Everything below concerns WADA. We keep the language plain, cite what the science says, and separate well-supported claims from open questions.
Last reviewed on 2026-03-22. Where a claim depends on a specific study, the study is described rather than over-claimed.
Laboratory identification of SR9009 typically relies on chromatographic separation coupled to mass spectrometry, often with ultraviolet detection as a secondary check. Nuclear magnetic resonance spectroscopy can confirm molecular structure when a reference standard is available. Because many suppliers sell the compound as a research chemical, independent identity testing is important for experimental reproducibility. A single retention time is not sufficient proof of identity, especially when related compounds may be present. Purity assessments usually report a percentage based on area normalization.
SR9009 is generally described as poorly soluble in water and more soluble in organic solvents such as dimethyl sulfoxide and ethanol. Stock solutions are commonly prepared in an organic solvent before dilution into an aqueous buffer or vehicle. Precipitation can occur if the organic fraction is reduced too quickly or if the final concentration exceeds the compound's solubility limit. Sonication or gentle warming may aid dissolution in some protocols, but excessive heat can promote degradation. Container material and pH can also influence observed solubility.
Analytical identification of SR9009 typically relies on liquid chromatography coupled with tandem mass spectrometry. In biological samples, researchers first separate the compound from matrix components using protein precipitation, liquid-liquid extraction, or solid-phase extraction. High-performance liquid chromatography with ultraviolet detection and nuclear magnetic resonance spectroscopy can support structural confirmation of reference materials. Because SR9009 is a small, relatively lipophilic molecule, reverse-phase columns and acidic mobile phases are common. Laboratories often include isotope-labeled internal standards to improve quantification and to correct for ion suppression.
Stability depends on physical form, temperature, light exposure, and solvent. Solid SR9009 is generally stored cold and dry, with protection from light to limit degradation. Dimethyl sulfoxide stocks are common for laboratory work, but repeated freeze-thaw cycles can reduce compound integrity. Aqueous solutions may be less stable than organic stocks, and the ethyl ester in the structure can be susceptible to hydrolysis under certain conditions. Researchers typically validate storage conditions and recheck purity before quantitative experiments, especially when using archived material.
Regulatory treatment of SR9009 varies by country and region. It is not approved as a pharmaceutical, and several jurisdictions restrict its sale for human consumption. Some authorities classify it as a research chemical, a prescription-only substance, or a prohibited performance-enhancing agent in sport. Purchasers may encounter certificates of analysis, but these documents do not guarantee identity, purity, or legality. In research settings, institutional safety reviews and controlled procurement help ensure that materials are handled under appropriate oversight. The absence of harmonized rules means that legal status can change and requires verification.
| Property | Value | Notes |
|---|---|---|
| Appearance | White to off-white powder | Visual inspection is not sufficient for identity. |
| Solubility | Soluble in DMSO and ethanol | Low solubility in water; stock solutions use organic solvent. |
| Storage | -20°C, desiccated, protected from light | Limits hydrolysis and photodegradation. |
| Analytical method | HPLC-UV/MS | Used for identity and purity assessment. |
| Synonyms | SR9009, Stenabolic | Naming varies by supplier. |
Storage recommendations for SR9009 reference material typically specify a freezer at -20 °C or lower, with protection from moisture and light. Repeated freeze-thaw cycles can degrade small molecules and introduce variability. Stock solutions in dimethyl sulfoxide are often aliquoted to avoid repeated handling. Stability studies may examine degradation under heat, humidity, and light exposure. The compound's thiophene and nitro groups can participate in reactions that alter analytical signals over time, so such changes affect quantitative results.
Quality control for research materials includes identity confirmation by nuclear magnetic resonance and purity assessment by high-performance liquid chromatography. Mass spectrometry provides molecular weight confirmation and can detect related impurities. Purchasers should request a certificate of analysis that lists lot-specific data. Online products advertised for human use often lack such documentation. Distinguishing legitimate research material from mislabeled or contaminated samples is a recurring challenge in independent testing, and independent laboratories may use orthogonal methods to verify identity.
Handling recommendations for SR9009 in a laboratory setting include storing the solid at low temperature, protected from light and moisture. The compound is often dissolved in dimethyl sulfoxide or ethanol for experiments. Solutions should be prepared with appropriate personal protective equipment and disposed of according to local rules. Stability data for long-term storage are limited, so stock solutions are typically kept cold and used within defined periods. Records of preparation date and concentration support reproducibility.
SR9009 is not approved as a medicine by major regulatory agencies. It is commonly sold as a research chemical, a category that may fall outside customary drug approval and quality rules. In sports, the World Anti-Doping Agency lists SR9009 as a prohibited substance. Athletes who use it can face sanctions if it is detected in a sample. Legal status varies by country, and importation may be restricted. Enforcement practices differ across borders.
Detection of SR9009 in biological samples usually employs liquid chromatography coupled with tandem mass spectrometry. This method can identify the parent compound and sometimes metabolites in urine or blood. Because exposure can be low and clearance may be rapid, sample timing and limits of detection matter. Laboratories validate assays for sensitivity and specificity. Results are interpreted alongside chain-of-custody and quality-control records. Urine is the common matrix for anti-doping analysis, while blood may be used in research settings.
Several misconceptions surround SR9009. It is often described as a SARM, a steroid, or an exercise pill, but its known target is the REV-ERB receptor family. Rodent studies have examined exercise capacity and metabolic markers, yet human outcomes remain unproven. Oral bioavailability appears low in animals, and human pharmacokinetics are not well characterized. Online products may contain impurities or different compounds, so identity and purity testing are important for research use.
Analytical chemists detect SR9009 with liquid chromatography-tandem mass spectrometry, commonly abbreviated LC-MS/MS. Sample preparation may involve protein precipitation, liquid-liquid extraction, or solid-phase extraction before analysis. Laboratories can target the parent compound or its metabolites, depending on the matrix and the purpose of testing. Anti-doping methods require sensitive and specific assays because concentrations in biological samples can be low. Reference standards and validated methods are essential for reliable identification and quantification.
Detection in biological samples can be complicated by rapid metabolism and low circulating concentrations. Some studies report phase I and phase II metabolites, and analytical methods may need to target those species in addition to the parent compound. Immunoassays are not broadly available, so mass spectrometry remains the main confirmatory approach. For anti-doping testing, laboratories look for SR9009 and its metabolites using validated LC-MS methods. Open questions include how long metabolites remain detectable and how different routes of administration alter detection windows.
In laboratory settings, SR9009 is typically characterized by liquid chromatography–mass spectrometry (LC-MS) or high-performance liquid chromatography with ultraviolet detection (HPLC-UV). These methods can confirm identity and estimate purity, but they require reference standards for accurate quantification. Because SR9009 is not a licensed pharmaceutical, no harmonized pharmacopeial monograph exists. Laboratories often validate in-house methods for matrices such as plasma, urine, or cell culture media. Sample preparation may involve protein precipitation or liquid-liquid extraction before analysis.
Physicochemical behavior influences handling. SR9009 is described as a solid with limited aqueous solubility, so organic solvents such as dimethyl sulfoxide or ethanol are common in research stock solutions. Aqueous dilution can produce precipitates if the organic content is too low. Light, heat, and repeated freeze-thaw cycles may affect stability. Storage recommendations usually specify a desiccated freezer environment protected from light, but exact stability data depend on the formulation and matrix.
In February 2020, the UK FSA advised vulnerable people, such as pregnant women, breastfeeding mothers, and those already taking medication for other medical concerns not to take CBD. The FSA further recommended that healthy adults should not consume more than 70 mg CBD per day.
A study on Neanderthal teeth from the Chagyrskaya Cave in the Altai Mountains (Russia), indicating that the studied sample overall falls within the known Neanderthal phenotypic variability but also preserves specific morphological traits, is published by Gicqueau et al. (2026). Massilani et al. (2026) present a high-quality genome of an approximately 110,000-years-old Neanderthal individual from the Denisova Cave (Russia), providing evidence of a closer relationship of the studied individual to a 120,000-years-old Neanderthal from the same cave than to a 80,000-years-old individual from the Chagyrskaya Cave or to European Neanderthals, evidence of gene flow from Denisovans in both Neanderthals from the Denisova Cave, and evidence of differentiation between Altai and European Neanderthals comparable to that of the most differentiated populations of modern humans. Zubova et al. (2026) report evidence of deliberate invasive dental caries intervention in a 59,000-years-old Neanderthal molar from the Chagyrskaya Cave. Evidence from the study of rhinocerotid remains from Middle Paleolithic sites in France and Spain, interpreted as consistent with use of rhinoceros teeth as tools (including soft hammers and anvils) by Neanderthals, is presented by Sanz-Royo et al. (2026). Picin et al.
== Synthesis == The synthesis (in this case, of carbon-14-labelled material) can be seen in figure 1. In the first step, o-nitroaniline (compound 1) is purified through dissolution in hot water-ethanol mixture in relation 2:1. [Activated carbon] is added and the result is filtrated for clarifying. The filtrate is chilled while kept in movement to generate crystals, usually at 4 °C, but if needed it can also be cooled to −10 °C. The crystals are then collected, washed and dried. If it is pure enough it is used for the following steps, which take place at 0 till 5 °C. To produce o-Nitrobenzonitrile-14C (compound 2), the first component o-nitroaniline and (concentrated reagent grade) hydrochloric acid are put together with ice and water. Sodium nitrite, dissolved in water, is added to this thin slurry. After the formation of a pale-yellow solution, which indicates the completion of the diazotization reaction, the pH should be adjusted to 6. After this, the solution is introduced to a mixture of cuprous cyanide and toluene. At room temperature the toluene layer is removed. The aqueous layer is washed and dried and the purified product is isolated by crystallization. The third product is Anthranilamide-14C (compound 3). It is formed out of o-Nitrobenzonitrile-14C, which is first solved in ethanol and hydrazine hydrate. The solvent is heated subsequently, treated in a well-ventilated hood with small periodic charges, smaller than 10 mg, of Raney nickel. Under nitrogen atmosphere the ethanolic solution is clarified and dried.
Sources: en.wikipedia.org
=== Telescopes === Solar Submillimeter Telescope, located in the "El Leoncito" Astronomical Complex Space Surveillance Telescope, a military telescope located at Exmouth, Western Australia. Spitzer Space Telescope, NASA infrared space observatory Swedish Solar Telescope
More generally, an NAD(P)H-hydrate epimerase (EC 5.1.99.6, NAD(P)HX epimerase) is a type of enzyme with systematic name (6R)-6beta-hydroxy-1,4,5,6-tetrahydronicotinamide-adenine dinucleotide 6-epimerase. Enzymes of this class, especially NAXE and its orthologs, catalyse the following chemical reaction
The petroleum industry generally classifies crude oil by the geographic location it is produced in (e.g., West Texas Intermediate, Brent, or Oman), its API gravity (an oil industry measure of density), and its sulfur content. Crude oil may be considered light if it has low density, heavy if it has high density, or medium if it has a density between that of light and heavy. Additionally, it may be referred to as sweet if it contains relatively little sulfur or sour if it contains substantial amounts of sulfur. The geographic location is important because it affects transportation costs to the refinery. Light crude oil is more desirable than heavy oil since it produces a higher yield of gasoline, while sweet oil commands a higher price than sour oil because it has fewer environmental problems and requires less refining to meet sulfur standards imposed on fuels in consuming countries. Each crude oil has unique molecular characteristics which are revealed by the use of crude oil assay analysis in petroleum laboratories. Barrels from an area in which the crude oil's molecular characteristics have been determined and the oil has been classified are used as pricing references throughout the world. Some of the common reference crudes are:
==== Catalonia ==== The 2009–2011 Catalan independence referendums, a series of non-binding and unofficial referendums, "popular votes" (consultes populars), took place in municipalities around Catalonia. In them voters indicated whether they supported Catalan independence from Spain. The first such referendum took place in Arenys de Munt on 13 September 2009: there followed votes in Sant Jaume de Frontanyà on 12 December and in 166 other municipalities on 13 December. Another vote ensued in April 2011 in Barcelona. Provisional figures for the 13 December vote suggest a turnout of around 200,000 (30% of those eligible to vote). The 2012 Catalan independence demonstration was a protest march which occurred in central Barcelona in Catalonia, Spain, on 11 September 2012 during the National Day of Catalonia. Many newspapers and other news agencies described it as a "historic" demonstration and considered it to be the biggest protest march ever held in Catalonia since the restoration of democracy in Spain, surpassing other major demonstrations, including the 2010 Catalan autonomy protest. A non-binding Catalan self-determination referendum was held on Sunday, 9 November 2014, to gauge support on the political future of Catalonia. While also referred to as "Catalan independence referendum", the vote was rebranded as a "participation process" by the Government of Catalonia, after a "non-referendum popular consultation" on the same topic and for the same date had been suspended by the Constitutional Court of Spain.
Sources: en.wikipedia.org
Liquid chromatography with mass spectrometry is a common approach. Ultraviolet detection and nuclear magnetic resonance can support identification when suitable standards are available.
The solid is generally kept cold, dry, and protected from light. Solutions are often frozen in single-use aliquots to reduce repeated freeze-thaw cycles.
It indicates a material sold for laboratory study, not for human use. The label does not guarantee pharmaceutical purity, sterility, or regulatory approval.
The most common approach is liquid chromatography-tandem mass spectrometry, often after extraction from blood, urine, or tissue. Ultraviolet detection and nuclear magnetic resonance spectroscopy are used mainly for reference material characterization. Isotope-labeled internal standards improve accuracy.